电气专业毕业设计外文翻译XF110KV变电所设计变压器.doc
《电气专业毕业设计外文翻译XF110KV变电所设计变压器.doc》由会员分享,可在线阅读,更多相关《电气专业毕业设计外文翻译XF110KV变电所设计变压器.doc(8页珍藏版)》请在沃文网上搜索。
1、TRANSFORMER1. INTRODUCTIONThe high-voltage transmission was need for the case electrical power is to be provided at considerable distance from a generating station. At some point this high voltage must be reduced, because ultimately is must supply a load. The transformer makes it possible for variou
2、s parts of a power system to operate at different voltage levels. In this paper we discuss power transformer principles and applications.2. TOW-WINDING TRANSFORMERSA transformer in its simplest form consists of two stationary coils coupled by a mutual magnetic flux. The coils are said to be mutually
3、 coupled because they link a common flux.In power applications, laminated steel core transformers (to which this paper is restricted) are used. Transformers are efficient because the rotational losses normally associated with rotating machine are absent, so relatively little power is lost when trans
4、forming power from one voltage level to another. Typical efficiencies are in the range 92 to 99%, the higher values applying to the larger power transformers.The current flowing in the coil connected to the ac source is called the primary winding or simply the primary. It sets up the flux in the cor
5、e, which varies periodically both in magnitude and direction. The flux links the second coil, called the secondary winding or simply secondary. The flux is changing; therefore, it induces a voltage in the secondary by electromagnetic induction in accordance with Lenzs law. Thus the primary receives
6、its power from the source while the secondary supplies this power to the load. This action is known as transformer action.3. TRANSFORMER PRINCIPLESWhen a sinusoidal voltage Vp is applied to the primary with the secondary open-circuited, there will be no energy transfer. The impressed voltage causes
7、a small current I to flow in the primary winding. This no-load current has two functions: (1) it produces the magnetic flux in the core, which varies sinusoidally between zero and m, where m is the maximum value of the core flux; and (2) it provides a component to account for the hysteresis and eddy
8、 current losses in the core. There combined losses are normally referred to as the core losses.The no-load current I is usually few percent of the rated full-load current of the transformer (about 2 to 5%). Since at no-load the primary winding acts as a large reactance due to the iron core, the no-l
9、oad current will lag the primary voltage by nearly 90. It is readily seen that the current component Im= I0sin0, called the magnetizing current, is 90 in phase behind the primary voltage VP. It is this component that sets up the flux in the core; is therefore in phase with Im.The second component, I
10、e=I0sin0, is in phase with the primary voltage. It is the current component that supplies the core losses. The phasor sum of these two components represents the no-load current, orI0 = Im+ IeIt should be noted that the no-load current is distortes and nonsinusoidal. This is the result of the nonline
11、ar behavior of the core material.If it is assumed that there are no other losses in the transformer, the induced voltage In the primary, Ep and that in the secondary, Es can be shown. Since the magnetic flux set up by the primary winding,there will be an induced EMF E in the secondary winding in acc
12、ordance with Faradays law, namely, E=N/t. This same flux also links the primary itself, inducing in it an EMF, Ep. As discussed earlier, the induced voltage must lag the flux by 90, therefore, they are 180 out of phase with the applied voltage. Since no current flows in the secondary winding, Es=Vs.
13、 The no-load primary current I0 is small, a few percent of full-load current. Thus the voltage in the primary is small and Vp is nearly equal to Ep. The primary voltage and the resulting flux are sinusoidal; thus the induced quantities Ep and Es vary as a sine function. The average value of the indu
14、ced voltage given byEavg = turnswhich is Faradays law applied to a finite time interval. It follows thatEavg = N = 4fNmwhich N is the number of turns on the winding. Form ac circuit theory, the effective or root-mean-square (rms) voltage for a sine wave is 1.11 times the average voltage; thusE = 4.4
15、4fNmSince the same flux links with the primary and secondary windings, the voltage per turn in each winding is the same. HenceEp = 4.44fNpmandEs = 4.44fNsmwhere Ep and Es are the number of turn on the primary and secondary windings, respectively. The ratio of primary to secondary induced voltage is
16、called the transformation ratio. Denoting this ratio by a, it is seen thata = = Assume that the output power of a transformer equals its input power, not a bad sumption in practice considering the high efficiencies. What we really are saying is that we are dealing with an ideal transformer; that is,
17、 it has no losses. ThusPm = PoutorVpIp primary PF = VsIs secondary PFwhere PF is the power factor. For the above-stated assumption it means that the power factor on primary and secondary sides are equal; thereforeVpIp = VsIsfrom which is obtained = aIt shows that as an approximation the terminal vol
18、tage ratio equals the turns ratio. The primary and secondary current, on the other hand, are inversely related to the turns ratio. The turns ratio gives a measure of how much the secondary voltage is raised or lowered in relation to the primary voltage. To calculate the voltage regulation, we need m
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10 积分
下载 | 加入VIP,下载更划算! |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 电气专业 毕业设计 外文 翻译 XF110KV 变电所 设计 变压器