1、 Technology and Application of Fieldbus Control System -Intelligent Equipment & Measurement And Control System Based on DeviceNetPromoted by the new technological revolution that automation control technology is tending digitization and internet in the field of automation industry, Shanghai Aton Ele
2、ctric Co., Ltd. developed Intelligent Equipment & Measurement And Control System Based on DeviceNet as a high and new technology industrialization model project. It was a state hi-tech development project of 2000 and was approved by the State Committee of Technology. Shanghai Aton Electric Co., Ltd.
3、 constructed production line of intelligent controller of pump and valve, relying on Shanghai Electric (Group) Corporation; constructed measurement and control system FCS R&D center of intelligent controller of pump and valve and built up mass production R&D basis, cooperating with Shanghai Jiaotong
4、 University and Shanghai University; constructed FCS remote diagnosis and service center of intelligent controller of pump and valve; constructed FCS training center of intelligent controller of pump and valve; founded mass production R&D basis along with the Rockwell Laboratory of Shanghai Jiaotong
5、 University and CIMS Center.1 Summary (1)Fieldbus control system is a system applied to field of production and microcomputerized measurement control equipment to realize both-way multinode serial communications. It is also called low-level control network for open, digital and multiplespot communic
6、ations. Application: Flow Control System of Manufacturing; Process Control System; Traffic Control & Management; Building Automation. Features: Fieldbus control system is low-level low-bandwidth digital communication and control network in industrial system as well as open system connecting microcom
7、puterized appearance. Intelligent instrument and controller are equal to microcomputer. They make up network with Fieldbus control system as the links to complete digital communication and other tasks. (2)Difference between FCS and DCS,FCS is updated control system after DCS integrated with digital
8、control system and distributing control system. It solves the problem that in traditional DCS, devices made by different manufacturers cannot be connected. They cant realize exchange and operation to organize an network system with wider range of information sharing. It conquers the defect that spec
9、ial closed system for network should be used for communication in DCS to realize various functions of integrated automation. It turns the distributing structure combining concentration with deconcentration in DCS into new-type full distributing structure. It releases the control function to the fiel
10、d thoroughly and makes it possible to realize basic control function by means of fieldbus equipment itself. FCS breaks the traditional structure form of control system. The traditional analog control system adopts one-to-one equipment tie-wire and puts up connections respectively according to contro
11、l loop. FCS adopts intelligent field equipment to place the control module, all input/output modules that used to be in the control chamber of DCS into field equipment. Since field equipment has ability to communicate, the field measuring and transferring instruments can transfer signals to actuatin
12、g mechanism such as valve directly. Its control function can be fulfilled directly on the spot independent of the computer or control meter in the control chamber, which realizes thorough decentralized control. FCS adopts digital signals to replace analog signals so that multiple signals (including
13、multiple operating parameter values, device status and failure information) can be transferred on a pair of cables. Meanwhile, it can give power supply to several devices. No switched block for analog/digital or digital/analog is needed besides fieldbus. (3)Characteristics of FCS Open System; Intero
14、perability; replace ability of devices made by different manufacturers. Intelligentize and Autonomy; Field equipment completing basic functions of automatic control. Decentralized System Structure; Field Adaptability; Relatively Strong Interference Killing Feature and Safety Intelligentized local eq
15、uipment can save investment and quantity of hardware Saving installation expenses and cables Saving daily maintenance expenses Enhancing accuracy and reliability of system Enhancing initiativeness of system integration for users (4)Development Background and Trend of Fieldbus Control System,With the
16、 rapid development of computer and computer network, FCS has been rapidly developed as the interlinked communication network between the field intelligent devices in the field of process automation, building and traffic etc. Because FCS meets the needs that industrial control system is developing in
17、 the way of decentralization, network and intellectualized, it has become the focus of global industrial automation and been universally concerned by the whole world. FCS has caused great revolutions on the aspects of system structure and function system for the current production of automation inst
18、rument, distributing control system and programmable controller. It is predicted that FCS will be the general trends in a very long time in the future fore sure.2 APPLICATION OF RELAYThe product reliability generally refers to the operating reliability. It is defined as: the ability of accomplishing
19、 the specified function under prescribed conditions and in prescribed time. It consists of intrinsic reliability and application reliability. The intrinsic reliability is determined by product designing and manufacturing technique, and the application reliability is concerned with the correct applic
20、ation of users and the services provided by the manufacturer before and after selling. When using relay, the user should pay attention to the following items.2.1 Coil applied voltage It is best to choose the coil applicative voltage according to the rated voltage in design, or choose the voltage acc
21、ording to the temperature rising curve. Using any coil voltage that is less than the rated voltage will affect the operation of the relay. The coil operating voltage refers to the voltage that is applied between the coil terminals. The voltage value between the two terminals must be guaranteed, espe
22、cially when using enlargement circuit to energize the coil. Whereas, it will also affect the relay characteristics if the applied voltage exceeds the highest rated voltage. Exorbitant voltage will bring exorbitant coil temperature rising, especially in high temperature ambient. Exorbitant temperatur
23、e rising will damage the insulating material and affect the working safety of relay. For magnetic latching relay, energizing (or return) pulse width should not less than 3 times of the operating (or return) time, otherwise, the relay would be left on the middle-position state. When using solid-state
24、 components to energize the coil, the components dielectric strength must be above 80V, and the leakage of current must be as little as possible to ensure the relay to release. Energizing power source: Under 110% of the rated current, the adjusting ratio of the power source is less than 10% (or the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10 积分
下载 | 加入VIP,下载更划算! |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 电子信息工程 外文 翻译 文献 英文