1、英文翻译部分英文部分:Advanced control algorithms for steam temperature regulation of thermal power plants A.Sanchez-Lopez,G.Arroyo-Figueroa*,A.Villavicencio-RamirezInstituto de Investigaciones Electricas, Division de Sistemas de Control, Reforma No. 113, Colonia Palmira,Cuernavaca, Morelos 62490, MexicoReceiv
2、ed 5 February 2003; revised 6 April 2004; accepted 8 July 2004AbstractA model-based controller (Dynamic Matrix Control) and an intelligent controller (Fuzzy Logic Control) have been designed and implemented for steam temperature regulation of a 300 MW thermal power plant. The temperature regulation
3、is considered the most demanded control loop in the steam generation process. Both proposed controllers Dynamic Matrix Controller (DMC) and Fuzzy Logic Controller (FLC) were applied to regulate superheated and reheated steam temperature. The results show that the FLC controller has a better performa
4、nce than advanced model-based controller, such as DMC or a conventional PID controller. The main benefits are the reduction of the overshoot and the tighter regulation of the steam temperatures. FLC controllers can achieve good result for complex nonlinear processes with dynamic variation or with lo
5、ng delay times.Keywords: Thermal power plants; Power plant control; Steam temperature regulation; Predictive control; Fuzzy logic control1. IntroductionCurrent economic and environment factors put a stringer requirement on thermal power plants to be operated at a high level of efficiency and safety
6、at minimum cost. In addition, there are an increment of the age of thermal plants that affected the reliability and performance of the plants. These factors have increased the complexity of power control systems operations 1,2.Currently, the computer and information technology have been extensively
7、used in thermal plant process operation and control. Distributed control systems (DCS) and management information systems (MIS) have been playing an important role to show the plant status. The main function of DCS is to handle normal disturbances and maintain key process parameters in pre-specified
8、 local optimal levels. Despite their great success, DCS have little function for abnormal and non-routine operation because the classical proportional-integral-derivative (PID) controlis widely used by the DCS. PID controllers exhibit poor performance when applied to process containing unknown non-l
9、inearity and time delays. The complexity of these problems and the difficulties in implementing conventional controllers to eliminate variations in PID tuning motivate the use of other kind of controllers, such as model-based controllers and intelligent controllers. This paper proposes a model-based
10、 controller such as Dynamic Matrix Controller (DMC) and an intelligent controller based on fuzzy logic as an alternative control strategy applied to regulate the steam temperature of the thermal power plant. The temperature regulation is considered the most demanded control loop in the steam generat
11、ion process. The steam temperature deviation must be kept within a tight variation rank in order to assure safe operation, improve efficiency and increase the life span of the equipment. Moreover, there are many mutual interactions between steam temperature control loops that have been considered. O
12、ther important factor is the time delay. It is well know that the time delay makes the temperature loops hard to tune. The complexity of these problems and difficulties to implement PID conventional controllers motivate to research the use of model predictive controllerssuch as the DMC or intelligen
13、t control techniques such as the Fuzzy Logic Controller (FLC) as a solution for controlling systems in which time delays, and non-linear behavior need to be addressed 3,4. The paper is organized as follows. A brief description of the DMC is presented in Section 2. The FLC design is described in Sect
14、ion 3. Section 4 presents the implementation of both controllers DMC and FLC to regulate the superheated and reheated steam temperature of a thermal power plant. The performance of the FLC controller was evaluated against two other controllers, the conventional PID controller and the predictive DMC
15、controller. Results are presented in Section 5. Finally, the main set of conclusions according to the analysis and results derived from the performance of controllers is presented in Section 6.2. Dynamic matrix controlThe DMC is a kind of model-based predictive control (Fig. 1). This controller was
16、developed to improve control of oil refinement processes 5. The DMC and other predictive control techniques such as the Generalized Predictive Control 6 or Smith predictor 6 algorithms are based on past and present information of controlled and manipulated variables to predict the future state of th
17、e process.The DMC is based on a time domain model. This model is utilized to predict the future behavior of the process in a defined time horizon (Fig. 2). Based on this precept the control algorithm provides a way to define the process behavior in the time, predicting the controlled variables traje
18、ctory in function of previous control actions and current values of the process 7. Controlled behavior can be obtained calculating the suitable future control actions. To obtain the process model, the system is perturbed with an unitary step signal as an input disturbance (Fig. 3).This method is the
19、 most common and easy mean to obtain the dynamic matrix coefficients of the process. The control technique includes the followings procedures:(a) Obtaining the Dynamic Matrix model of the process. In this stage, a step signal is applied to the input of the process. The measurements obtained with thi
20、s activity represent the process behavior as well as the coefficients of the process state in time. This step is performed just once before the operation of the control algorithm in the process.(b) Determination of deviations in controlled variables. In this step, the deviation between the controlle
21、d variables of the process and their respective set points is measured.(c) Projection of future states of the process. The future behavior of each controlled variable is defined ina vector. This vector is based on previous control actions and current values of the process.(d) Calculation of control
22、movements. Control movements are obtained using the future vector of error and the dynamic matrix of the process. The equation developed to obtain the control movements is shown below:where A represents the dynamic matrix, AT the transpose matrix of A X the vector of future states of the process, f
23、a weighting factor, I the image matrix and D he future control actions. Further details about this equation are found in Ref. 5.(e) Control movements implementation. In this step the first element of the control movements vector is applied to manipulated variables. A DMC controller allows designers
24、the use of time domain information to create a process model. The mathematical method for prediction matches the predicted behavior and the actual behavior of the process to predict the next state of the process. However, the process model is not continuously updated because this involves recalculat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
20 积分
下载 | 加入VIP,下载更划算! |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 外文 翻译 火力发电厂 先进 蒸汽 温度 调节 控制 算法